这是描述信息

EPOWER INTERNATIONAL ( SHANGHAl )CO.,LTD.

Product Center
产品分类
Number of views:
1000

KYN28 high voltage power distribution cabinet

KYN28-12 metal armored central switchgear is designed according to the armored metal enclosed switchgear in GB3906-2006. It is suitable for three-phase AC rated voltage 12kV, rated frequency 50Hz power system, used to receive and distribute electric energy well to control the circuit. Protection and detection.
Product serial number
Product description
Parameters

Brief introduction of KYN28-12 metal armored central switch cabinet

KYN28-12 metal armored central switchgear is designed according to the armored metal enclosed switchgear in GB3906-2006. It is suitable for three-phase AC rated voltage 12kV, rated frequency 50Hz power system, used to receive and distribute electric energy well to control the circuit. Protection and detection.

 

Environmental conditions for use:

Normal environmental conditions
1. The upper limit of ambient air temperature: +40°. Lower limit: -15°.
2.Altitude: no more than 3000m and below.
3.Relative ambient temperature: daily average not more than 95%, monthly average not more than 90%.
4.Earthquake: The intensity does not exceed 8 degrees.
5.The surrounding air is not significantly polluted by corrosive or combustible gas, water vapor, etc.
6.No serious pollution and frequent severe vibration, severe design under severe conditionsMeet Class 1 requirements.

 

Standards compliant:

GB3906- 2006

"3- 35kV AC is all enclosed switchgear"

GB11022-89

"General Technical Requirements for High Voltage Switchgear"

IEC60298

"AC metal-enclosed switchgear and control equipment with rated voltage above 1kV and 50kV and below"

DL404-97

"Technical Conditions for Ordering Indoor AC High Voltage Switchgear"

 

Technical index:

1.Rated voltage (KV) 12KV
2.Power frequency withstand voltage (KV) 42 (1min)
3.Xiaodian impulse withstand voltage (KV) 75
4.Rated frequency 50Hz
5.Rated current (A) 630. 1250
6.Rated short-time withstand current 25KA 4S
7.Rated voltage of opening and closing and auxiliary circuit (V) DC 24, 36. 48, 60,
110, 220, exchange 110, 220
B.Protection grade IP3X. IP4X

Structure introduction:

The switchgear is designed according to the armored metal-enclosed switchgear in GB3906--2006. The whole is composed of two parts: a cabinet and a middle-mounted withdrawable part (ie, a handcart). The cabinet is divided into four separate compartments, the enclosure protection level is IP4X, and the protection level of each compartment and circuit breaker room is IP2X when the door is opened. With overhead incoming and outgoing lines, cable incoming and outgoing lines and other functional schemes, arranged. After being combined, it can become a power distribution device of various schemes.

A.Busbar room B. Circuit breaker handcart room
C.Cable room D. Relay instrument room

01.shell

12. Removable partition

02.Branch bus

13.Partition (trap)

03.Bus bushing

14.Secondary plug

04.Main bus

15.Circuit breaker handcart

05.Static column head device

16. heating equipment

06.Contact box

17.Withdrawable horizontal partition

07.Current Transformer

18.Earthing switch operating mechanism

08.Earthing switch

19.Bottom plate

09.cable

20.Pressure relief device

10.lightning arrester

21.Control wire duct

11.Ground bus

 

We could not find any corresponding parameters, please add them to the properties table

EPOWER INTERNATIONAL ( SHANGHAl )CO.,LTD.

 

Company Address: 4th Floor, Unit 7, No.159 Tianzhou Road, Xuhui District, Shanghai
Tel:
86-21-54452800
Email:shenlong@epower88.com
Web:www.quanfeng.com

Copyright © 2021 Quanfeng Electromechanical International Trade (Shanghai) Co., Ltd. All Rights Reserved    ICP备13018365号     300.cn    shanghai